hyperspy.external.mpfit package

Submodules

hyperspy.external.mpfit.mpfit module

Perform Levenberg-Marquardt least-squares minimization, based on MINPACK-1.

AUTHORS

The original version of this software, called LMFIT, was written in FORTRAN as part of the MINPACK-1 package by XXX.

Craig Markwardt converted the FORTRAN code to IDL. The information for the IDL version is:

Craig B. Markwardt, NASA/GSFC Code 662, Greenbelt, MD 20770 craigm@lheamail.gsfc.nasa.gov UPDATED VERSIONs can be found on my WEB PAGE:

Mark Rivers created this Python version from Craig’s IDL version.
Mark Rivers, University of Chicago Building 434A, Argonne National Laboratory 9700 South Cass Avenue, Argonne, IL 60439 rivers@cars.uchicago.edu Updated versions can be found at http://cars.uchicago.edu/software
Sergey Koposov converted the Mark’s Python version from Numeric to numpy

Sergey Koposov, University of Cambridge, Institute of Astronomy, Madingley road, CB3 0HA, Cambridge, UK koposov@ast.cam.ac.uk Updated versions can be found at http://code.google.com/p/astrolibpy/source/browse/trunk/

DESCRIPTION

MPFIT uses the Levenberg-Marquardt technique to solve the least-squares problem. In its typical use, MPFIT will be used to fit a user-supplied function (the “model”) to user-supplied data points (the “data”) by adjusting a set of parameters. MPFIT is based upon MINPACK-1 (LMDIF.F) by More’ and collaborators.

For example, a researcher may think that a set of observed data points is best modelled with a Gaussian curve. A Gaussian curve is parameterized by its mean, standard deviation and normalization. MPFIT will, within certain constraints, find the set of parameters which best fits the data. The fit is “best” in the least-squares sense; that is, the sum of the weighted squared differences between the model and data is minimized.

The Levenberg-Marquardt technique is a particular strategy for iteratively searching for the best fit. This particular implementation is drawn from MINPACK-1 (see NETLIB), and is much faster and more accurate than the version provided in the Scientific Python package in Scientific.Functions.LeastSquares. This version allows upper and lower bounding constraints to be placed on each parameter, or the parameter can be held fixed.

The user-supplied Python function should return an array of weighted deviations between model and data. In a typical scientific problem the residuals should be weighted so that each deviate has a gaussian sigma of 1.0. If X represents values of the independent variable, Y represents a measurement for each value of X, and ERR represents the error in the measurements, then the deviates could be calculated as follows:

DEVIATES = (Y - F(X)) / ERR

where F is the analytical function representing the model. You are recommended to use the convenience functions MPFITFUN and MPFITEXPR, which are driver functions that calculate the deviates for you. If ERR are the 1-sigma uncertainties in Y, then

TOTAL( DEVIATES^2 )

will be the total chi-squared value. MPFIT will minimize the chi-square value. The values of X, Y and ERR are passed through MPFIT to the user-supplied function via the FUNCTKW keyword.

Simple constraints can be placed on parameter values by using the PARINFO keyword to MPFIT. See below for a description of this keyword.

MPFIT does not perform more general optimization tasks. See TNMIN instead. MPFIT is customized, based on MINPACK-1, to the least-squares minimization problem.

USER FUNCTION

The user must define a function which returns the appropriate values as specified above. The function should return the weighted deviations between the model and the data. It should also return a status flag and an optional partial derivative array. For applications which use finite-difference derivatives – the default – the user function should be declared in the following way:

def myfunct(p, fjac=None, x=None, y=None, err=None)
# Parameter values are passed in “p” # If fjac==None then partial derivatives should not be # computed. It will always be None if MPFIT is called with default # flag. model = F(x, p) # Non-negative status value means MPFIT should continue, negative means # stop the calculation. status = 0 return([status, (y-model)/err]

See below for applications with analytical derivatives.

The keyword parameters X, Y, and ERR in the example above are suggestive but not required. Any parameters can be passed to MYFUNCT by using the functkw keyword to MPFIT. Use MPFITFUN and MPFITEXPR if you need ideas on how to do that. The function must accept a parameter list, P.

In general there are no restrictions on the number of dimensions in X, Y or ERR. However the deviates must be returned in a one-dimensional Numeric array of type Float.

User functions may also indicate a fatal error condition using the status return described above. If status is set to a number between -15 and -1 then MPFIT will stop the calculation and return to the caller.

ANALYTIC DERIVATIVES

In the search for the best-fit solution, MPFIT by default calculates derivatives numerically via a finite difference approximation. The user-supplied function need not calculate the derivatives explicitly. However, if you desire to compute them analytically, then the AUTODERIVATIVE=0 keyword must be passed to MPFIT. As a practical matter, it is often sufficient and even faster to allow MPFIT to calculate the derivatives numerically, and so AUTODERIVATIVE=0 is not necessary.

If AUTODERIVATIVE=0 is used then the user function must check the parameter FJAC, and if FJAC!=None then return the partial derivative array in the return list.

def myfunct(p, fjac=None, x=None, y=None, err=None)

# Parameter values are passed in “p” # If FJAC!=None then partial derivatives must be comptuer. # FJAC contains an array of len(p), where each entry # is 1 if that parameter is free and 0 if it is fixed. model = F(x, p) Non-negative status value means MPFIT should continue, negative means # stop the calculation. status = 0 if (dojac):

pderiv = zeros([len(x), len(p)], Float) for j in range(len(p)):

pderiv[:,j] = FGRAD(x, p, j)
else:
pderiv = None

return([status, (y-model)/err, pderiv]

where FGRAD(x, p, i) is a user function which must compute the derivative of the model with respect to parameter P[i] at X. When finite differencing is used for computing derivatives (ie, when AUTODERIVATIVE=1), or when MPFIT needs only the errors but not the derivatives the parameter FJAC=None.

Derivatives should be returned in the PDERIV array. PDERIV should be an m x n array, where m is the number of data points and n is the number of parameters. dp[i,j] is the derivative at the ith point with respect to the jth parameter.

The derivatives with respect to fixed parameters are ignored; zero is an appropriate value to insert for those derivatives. Upon input to the user function, FJAC is set to a vector with the same length as P, with a value of 1 for a parameter which is free, and a value of zero for a parameter which is fixed (and hence no derivative needs to be calculated).

If the data is higher than one dimensional, then the last dimension should be the parameter dimension. Example: fitting a 50x50 image, “dp” should be 50x50xNPAR.

CONSTRAINING PARAMETER VALUES WITH THE PARINFO KEYWORD

The behavior of MPFIT can be modified with respect to each parameter to be fitted. A parameter value can be fixed; simple boundary constraints can be imposed; limitations on the parameter changes can be imposed; properties of the automatic derivative can be modified; and parameters can be tied to one another.

These properties are governed by the PARINFO structure, which is passed as a keyword parameter to MPFIT.

PARINFO should be a list of dictionaries, one list entry for each parameter. Each parameter is associated with one element of the array, in numerical order. The dictionary can have the following keys (none are required, keys are case insensitive):

‘value’ - the starting parameter value (but see the START_PARAMS
parameter for more information).
‘fixed’ - a boolean value, whether the parameter is to be held
fixed or not. Fixed parameters are not varied by MPFIT, but are passed on to MYFUNCT for evaluation.
‘limited’ - a two-element boolean array. If the first/second
element is set, then the parameter is bounded on the lower/upper side. A parameter can be bounded on both sides. Both LIMITED and LIMITS must be given together.
‘limits’ - a two-element float array. Gives the
parameter limits on the lower and upper sides, respectively. Zero, one or two of these values can be set, depending on the values of LIMITED. Both LIMITED and LIMITS must be given together.
‘parname’ - a string, giving the name of the parameter. The
fitting code of MPFIT does not use this tag in any way. However, the default iterfunct will print the parameter name if available.
‘step’ - the step size to be used in calculating the numerical
derivatives. If set to zero, then the step size is computed automatically. Ignored when AUTODERIVATIVE=0.
‘mpside’ - the sidedness of the finite difference when computing

numerical derivatives. This field can take four values:

0 - one-sided derivative computed automatically 1 - one-sided derivative (f(x+h) - f(x) )/h
-1 - one-sided derivative (f(x) - f(x-h))/h
2 - two-sided derivative (f(x+h) - f(x-h))/(2*h)

Where H is the STEP parameter described above. The “automatic” one-sided derivative method will chose a direction for the finite difference which does not violate any constraints. The other methods do not perform this check. The two-sided method is in principle more precise, but requires twice as many function evaluations. Default: 0.

‘mpmaxstep’ - the maximum change to be made in the parameter

value. During the fitting process, the parameter will never be changed by more than this value in one iteration.

A value of 0 indicates no maximum. Default: 0.

‘tied’ - a string expression which “ties” the parameter to other
free or fixed parameters. Any expression involving constants and the parameter array P are permitted. Example: if parameter 2 is always to be twice parameter 1 then use the following: parinfo(2).tied = ‘2 * p(1)’. Since they are totally constrained, tied parameters are considered to be fixed; no errors are computed for them. [ NOTE: the PARNAME can’t be used in expressions. ]
‘mpprint’ - if set to 1, then the default iterfunct will print the
parameter value. If set to 0, the parameter value will not be printed. This tag can be used to selectively print only a few parameter values out of many. Default: 1 (all parameters printed)

Future modifications to the PARINFO structure, if any, will involve adding dictionary tags beginning with the two letters “MP”. Therefore programmers are urged to avoid using tags starting with the same letters; otherwise they are free to include their own fields within the PARINFO structure, and they will be ignored.

PARINFO Example: parinfo = [{‘value’:0., ‘fixed’:0, ‘limited’:[0,0], ‘limits’:[0.,0.]}

for i in range(5)]

parinfo[0][‘fixed’] = 1 parinfo[4][‘limited’][0] = 1 parinfo[4][‘limits’][0] = 50. values = [5.7, 2.2, 500., 1.5, 2000.] for i in range(5): parinfo[i][‘value’]=values[i]

A total of 5 parameters, with starting values of 5.7, 2.2, 500, 1.5, and 2000 are given. The first parameter is fixed at a value of 5.7, and the last parameter is constrained to be above 50.

EXAMPLE

import mpfit import numpy.oldnumeric as Numeric x = arange(100, float) p0 = [5.7, 2.2, 500., 1.5, 2000.] y = ( p[0] + p[1]*[x] + p[2]*[x**2] + p[3]*sqrt(x) +

p[4]*log(x))

fa = {‘x’:x, ‘y’:y, ‘err’:err} m = mpfit(‘myfunct’, p0, functkw=fa) print(‘status = ‘, m.status) if (m.status <= 0): print(‘error message = ‘, m.errmsg) print(‘parameters = ‘, m.params)

Minimizes sum of squares of MYFUNCT. MYFUNCT is called with the X, Y, and ERR keyword parameters that are given by FUNCTKW. The results can be obtained from the returned object m.

THEORY OF OPERATION

There are many specific strategies for function minimization. One very popular technique is to use function gradient information to realize the local structure of the function. Near a local minimum the function value can be taylor expanded about x0 as follows:

f(x) = f(x0) + f’(x0) . (x-x0) + (1/2) (x-x0) . f’‘(x0) . (x-x0)
—– ————— ——————————- (1)

Order 0th 1st 2nd

Here f’(x) is the gradient vector of f at x, and f’‘(x) is the Hessian matrix of second derivatives of f at x. The vector x is the set of function parameters, not the measured data vector. One can find the minimum of f, f(xm) using Newton’s method, and arrives at the following linear equation:

f’‘(x0) . (xm-x0) = - f’(x0) (2)

If an inverse can be found for f’‘(x0) then one can solve for (xm-x0), the step vector from the current position x0 to the new projected minimum. Here the problem has been linearized (ie, the gradient information is known to first order). f’‘(x0) is symmetric n x n matrix, and should be positive definite.

The Levenberg - Marquardt technique is a variation on this theme. It adds an additional diagonal term to the equation which may aid the convergence properties:

(f’‘(x0) + nu I) . (xm-x0) = -f’(x0) (2a)

where I is the identity matrix. When nu is large, the overall matrix is diagonally dominant, and the iterations follow steepest descent. When nu is small, the iterations are quadratically convergent.

In principle, if f’‘(x0) and f’(x0) are known then xm-x0 can be determined. However the Hessian matrix is often difficult or impossible to compute. The gradient f’(x0) may be easier to compute, if even by finite difference techniques. So-called quasi-Newton techniques attempt to successively estimate f’‘(x0) by building up gradient information as the iterations proceed.

In the least squares problem there are further simplifications which assist in solving eqn (2). The function to be minimized is a sum of squares:

f = Sum(hi^2) (3)

where hi is the ith residual out of m residuals as described above. This can be substituted back into eqn (2) after computing the derivatives:

f’ = 2 Sum(hi hi’) f’’ = 2 Sum(hi’ hj’) + 2 Sum(hi hi’‘) (4)

If one assumes that the parameters are already close enough to a minimum, then one typically finds that the second term in f’’ is negligible [or, in any case, is too difficult to compute]. Thus, equation (2) can be solved, at least approximately, using only gradient information.

In matrix notation, the combination of eqns (2) and (4) becomes:

hT’ . h’ . dx = - hT’ . h (5)

Where h is the residual vector (length m), hT is its transpose, h’ is the Jacobian matrix (dimensions n x m), and dx is (xm-x0). The user function supplies the residual vector h, and in some cases h’ when it is not found by finite differences (see MPFIT_FDJAC2, which finds h and hT’). Even if dx is not the best absolute step to take, it does provide a good estimate of the best direction, so often a line minimization will occur along the dx vector direction.

The method of solution employed by MINPACK is to form the Q . R factorization of h’, where Q is an orthogonal matrix such that QT . Q = I, and R is upper right triangular. Using h’ = Q . R and the ortogonality of Q, eqn (5) becomes

(RT . QT) . (Q . R) . dx = - (RT . QT) . h
RT . R . dx = - RT . QT . h (6)
R . dx = - QT . h

where the last statement follows because R is upper triangular. Here, R, QT and h are known so this is a matter of solving for dx. The routine MPFIT_QRFAC provides the QR factorization of h, with pivoting, and MPFIT_QRSOLV provides the solution for dx.

REFERENCES

MINPACK-1, Jorge More’, available from netlib (www.netlib.org). “Optimization Software Guide,” Jorge More’ and Stephen Wright,

SIAM, Frontiers in Applied Mathematics, Number 14.
More’, Jorge J., “The Levenberg-Marquardt Algorithm:

Implementation and Theory,” in Numerical Analysis, ed. Watson, G. A., Lecture Notes in Mathematics 630, Springer-Verlag, 1977.

MODIFICATION HISTORY

Translated from MINPACK-1 in FORTRAN, Apr-Jul 1998, CM

Copyright (C) 1997-2002, Craig Markwardt This software is provided as is without any warranty whatsoever. Permission to use, copy, modify, and distribute modified or unmodified copies is granted, provided this copyright and disclaimer are included unchanged.

Translated from MPFIT (Craig Markwardt’s IDL package) to Python, August, 2002. Mark Rivers Converted from Numeric to numpy (Sergey Koposov, July 2008) Fixed the analytic derivatives features (The HyperSpy Developers, 2011)
class hyperspy.external.mpfit.mpfit.machar(double=1)

Bases: object

class hyperspy.external.mpfit.mpfit.mpfit(fcn, xall=None, functkw=None, parinfo=None, ftol=1e-10, xtol=1e-10, gtol=1e-10, damp=0.0, maxiter=200, factor=100.0, nprint=1, iterfunct='default', iterkw={}, nocovar=0, rescale=0, autoderivative=1, quiet=0, diag=None, epsfcn=None, debug=0)

Bases: object

blas_enorm32 = <fortran dnrm2>
blas_enorm64 = <fortran dnrm2>
calc_covar(rr, ipvt=None, tol=1e-14)
call(fcn, x, functkw, fjac=None)
defiter(fcn, x, iter, fnorm=None, functkw=None, quiet=0, iterstop=None, parinfo=None, format=None, pformat='%.10g', dof=1)
enorm(vec)
fdjac2(fcn, x, fvec, step=None, ulimited=None, ulimit=None, dside=None, epsfcn=None, autoderivative=1, functkw=None, xall=None, ifree=None, dstep=None)
lmpar(r, ipvt, diag, qtb, delta, x, sdiag, par=None)
parinfo(parinfo=None, key='a', default=None, n=0)
qrfac(a, pivot=0)
qrsolv(r, ipvt, diag, qtb, sdiag)
tie(p, ptied=None)

hyperspy.external.mpfit.mpfitexpr module

This program is free software: you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation, either version 3 of the License, or (at your option) any later version.

This program is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for more details.

You should have received a copy of the GNU General Public License along with this program. If not, see <http://www.gnu.org/licenses/>.

hyperspy.external.mpfit.mpfitexpr.mpfitexpr(func, x, y, err, start_params, check=True, full_output=False, imports=None, **kw)

Fit the used defined expression to the data Input: - func: string with the function definition - x: x vector - y: y vector - err: vector with the errors of y - start_params: the starting parameters for the fit Output: - The tuple (params, yfit) with best-fit params and the values of func evaluated at x Keywords: - check: boolean parameter. If true(default) the function will be checked for sanity - full_output: boolean parameter. If True(default is False) then instead of best-fit parameters the mpfit object is returned - imports: list of strings, of optional modules to be imported, required to evaluate the function Example: params,yfit=mpfitexpr(‘p[0]+p[2]*(x-p[1])’,x,y,err,[0,10,1])

If you need to use numpy and scipy functions in your function, then
you must to use the full names of these functions, e.g.: numpy.sin, numpy.cos etc.
This function is motivated by mpfitexpr() from wonderful MPFIT IDL package
written by Craig Markwardt

hyperspy.external.mpfit.test_mpfit module

hyperspy.external.mpfit.test_mpfit.Flin(x, p)
hyperspy.external.mpfit.test_mpfit.myfunctlin(p, fjac=None, x=None, y=None, err=None)
hyperspy.external.mpfit.test_mpfit.myfunctrosenbrock(p, fjac=None)
hyperspy.external.mpfit.test_mpfit.test_linfit()
hyperspy.external.mpfit.test_mpfit.test_rosenbrock()

Module contents